01 / 06
1. Know the two settings you must finish
A list’s Campaign field assigns its leads to a campaign. The campaign’s Manual Dial List ID is a separate default used by manual dialing. Creating the list does not automatically set that campaign field. Finish and reopen both records.
For a new course fixture use the values below. If an ID belongs to another activity, choose an unused course ID and write that substitution on your worksheet. Do not reassign someone else’s list. Keep LAB01 inactive for this lesson.
02 / 06
2. Create the empty list once
- Open Lists → Show Lists and search for90001 before creating anything.
- If90001 is absent, choose Add A New List, enter the fields below and SUBMIT.
- If90001 is already your earlier course list, open it instead; do not create a duplicate or remove its leads.
- Open90001 again from Show Lists so you check a saved record.
- List ID
- 90001The course list ID.
- List Name
- Practice listA readable name.
- List Description
- Fictional practice contactsDescribes its intended contents.
- Campaign
- LAB01Connects the list to the lab campaign.
- Active
- YMakes the list available to the campaign.
Steps and result8 steps
See the real List ID, name, Campaign and Active controls, followed by SUBMIT and the saved list.
Observed resultVICIdial returned LIST ADDED: 90001. Its saved Campaign is LAB01 and Active is Y. The list is empty at this stage.
Read the chapter notes
- Actual Add A New List form
Campaign LAB01 already exists and remains inactive.
- Open Add A New List
This is the actual VICIdial Administration form. Campaign LAB01 was created inactive in the preceding recording.
- Enter List ID 90001
Enter the unused numeric ID 90001.
- Name the list
Enter Practice list and Fictional practice contacts.
- Select campaign LAB01
Select LAB01 as Campaign, then set the list Active to Y. The campaign remains inactive.
- Submit the real list form
Click SUBMIT once.
- Verify the saved list
The actual result says LIST ADDED: 90001. Reopen the list to verify its campaign and Active value.
- Reopen the saved list
The actual modify form confirms list 90001, Campaign LAB01 and Active Y. The list is still empty before the upload.
November 4, 2026 · VICIdial Admin 2.14-969a · SVN 4037. Synthetic lab records; campaign LAB01 stays inactive. ViciGeek watermark is burned into the recording. Use fullscreen to read the original field labels.
View a still screenshot
Fill the initial list form
Open to enlargeCapture details
LAB01 and 90001 already exist in the capture lab, so no duplicate was submitted. Check for an unused ID in your own lab. The earlier saved-workflow recording has its separate actual confirmation. November 4, 2026; Admin 2.14-969a build261102-0125.You should seeA new list opens with Campaign LAB01 and Active Y. A fresh list has zero leads; a resumed course list may already have the three synthetic leads from the import lesson.
03 / 06
3. Check the saved list
On the reopened90001 page, confirm List Name Practice list, Campaign LAB01 and Active Y. Record the lead count. Zero is expected before import; three is expected only if you previously finished the course import. Any unfamiliar contacts or count require investigation before you continue.
Saved list assignment
Open to enlargeCapture details
Its three synthetic leads were imported in the earlier recording. Native Agent Browser capture of the saved synthetic lab record, November 6, 2026; no field was changed or submitted.You should seeYou have read the saved list-to-campaign relationship, rather than relying on the Add List form or a submit message.
04 / 06
4. Set the campaign’s Manual Dial List ID
Open Campaigns → Show Campaigns → LAB01. Use the Detail view if the field is absent, then browser Find for Manual Dial List ID. Record its prior value before editing. The reviewed fixture initially showed998; the approved exercise saved90001 and reopened it below.
- Confirm you are editing LAB01, not another campaign.
- Set Manual Dial List ID to 90001. Leave Active N and Auto Dial Level 0.
- Select SUBMIT. Return to Show Campaigns, open LAB01 again and find Manual Dial List ID.
- Read the saved value: it must be90001. If it still shows998 or a different value, the task has not passed.
- Manual Dial List ID
- 90001Use your substituted list ID if90001 was already owned by something else.
The saved mapping after the correction
Open to enlargeCapture details
The field was later restored to its prior998 value during rollback; this capture is evidence of the completed mapping step.Before: the missing mapping
Open to enlargeYou should seePass only when the reopened LAB01 field shows90001. An unchanged screenshot or an unsaved text-box value is not enough.
05 / 06
5. Compare both records
Complete this small record while both pages are available. The value you read after reopening matters more than the value you intended to type.
- Before you use it
- Fill this with your own observed values; it contains no passwords.
Fixture campaign: LAB01Fixture list: 90001Prior Manual Dial List ID: __________Reopened list Campaign: __________Reopened list Active: __________Reopened campaign Manual Dial List ID: __________Lead count before import/resume: __________Checked at (server time): __________- Success looks like
- Campaign LAB01 + list Active Y + Manual Dial List ID 90001 all match. A fresh list count is0; a resumed completed import is3.
- Stop if
- If one relationship differs, return to that saved record before importing or dialing.
Steps and result5 steps
Actual native VICIdial controls, filled with example values in the browser. This recording stops before submission. Use the field notes to distinguish lab fixtures, missing prerequisites and deployment-specific values.
Entry shownReal native Modify controls with example values entered only in browser state. The form was not submitted; no configuration, route, permission, registration or call was changed.
Read the chapter notes
- Actual native form — not submitted
Real native Modify controls with example values entered only in browser state. The form was not submitted; no configuration, route, permission, registration or call was changed.
- Name the practice list
This example name is entered only in browser state on the existing list detail form.
- Select LAB01 and Active Y
LAB01 is a real native campaign option. These unsaved changes do not prove lead eligibility.
- Do not reset called status
Reset Lead-Called-Status remains N. Nothing is submitted.
- Review the unsaved example
Real native Modify controls with example values entered only in browser state. The form was not submitted; no configuration, route, permission, registration or call was changed.
November 4, 2026 · VICIdial 2.14-969a build 261102-0125. Real native Modify controls with example values entered only in browser state. The form was not submitted; no configuration, route, permission, registration or call was changed. ViciGeek attribution is encoded in the video and poster. Use fullscreen to read the original field labels.
You should seeBoth saved relationships match your worksheet. No call or lead import is required to finish this lesson.
06 / 06
Resolve a mismatch without losing records
- LAB01 missing from the list’s Campaign menu: open Show Campaigns and verify its ID and administrator visibility. Complete the campaign lesson if it does not exist.
- 90001 belongs to another campaign: leave it untouched and choose an unused list ID. Use that new ID in both relationships and the CSV import target.
- Manual Dial List ID is absent: open the campaign’s Detail view and confirm administrator permission; a basic view may omit advanced fields.
- A save is rejected or the old value returns: read the named validation error, reopen the same campaign and verify the selected record before retrying.
- Wrong assignment saved on your disposable fixture: first confirm no other workflow uses it, then restore the previously recorded Campaign or Manual Dial List ID and reopen both records. Keep the campaign inactive.
- Leads already exist: inspect their synthetic identifiers. Do not delete the list, reset statuses or reimport blindly to make a screenshot look empty.
Checks and sources
What was checked
- The November 4 recording saved list 90001 under LAB01 and imported three synthetic leads. A November 6 read-only reopen confirmed that assignment.
- During the approved November 6 exercise, Manual Dial List ID was changed from998 to 90001, saved and reopened in the native campaign screen. Both the before and prepared-state captures are retained. After the test the prior998 value was restored, so the prepared screenshot records that moment, not the current rollback state.
Primary references
Sources
- VICIdial public demonstrationVICIdial · accessed November 3, 2026
- VICIdial nightly sourceVICIdial · accessed November 3, 2026



